Adjustments

Gas Burner Air Shutter

NOTE: Air inlet shutters on the burner must be
adjusted so sufficient air is metered into the system
for proper combustion and maximum efficiency.
Before adjusting the inlet shutters be sure that all
lint is removed from lint compartments and lint
screen.

Air shutter adjustments will vary from location to

location and will depend on the vent system, number

of units installed, make-up air and line gas pressure.

Opening the shutter increases the amount of primary

air supplied to the burner while closing the shutter

decreases the primary air supply. Adjust air shutter as

follows:
Refer to Figure 18.

1. Open the access panel.
2. Start the tumbler and check the flame pattern. If

the flame pattern is straight up, insufficient air is

flowing through the tumbler and air flow switch

is improperly set. A flame pattern that flares to

the right and left indicates no air is flowing

through the tumbler.

3. Correct air and gas mixture is indicated if the

flame pattern is primarily blue, with small yellow

tips, and bends to the right of the heater section.

Too little air is indicated if the flame if yellow,

lazy and smokey.

4. To adjust the air shutter, loosen air inlet shutter

adjusting screw.

5. Open or close air shutter as necessary to obtain

proper flame intensity.

6. After air shutter is adjusted for proper flame,

tighten air shutter adjusting screw securely.

Figure 18

T457I

1

Air Shutter Adjusting Screws

T457I

1

PROPER AIRFLOW

INSUFFICIENT AIRFLOW

NO AIRFLOW

1

1