Installation

19

70256801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Before Placing Tumbler into Service

1. Remove or open all panels and check accessible

bolts, nuts, screws, terminals and fittings for

tightness.

2. Check belt tension and adjust if necessary. Refer

to Adjustments Section.

3. Replace all panels and guards.
4. Turn on electrical supply to tumbler.
5. Open the supply valve for gas or steam heated

tumblers.

6. After performing the previous checks, start the

tumbler by pressing START. (Refer to the
Operating Manual

for detailed instructions.)

Release the start button and open the loading

door. The cylinder should stop rotating within

seven seconds after the door is opened.

7. Gas models: Start the tumbler and check the

burner flame. Adjust the air inlet shutter as

required. Refer to Adjustments Section.

IMPORTANT: Refer to Table 2. The electronic
ignition system will attempt to light the gas by
sparking for the “trial for ignition” period. If gas
does ignite within this period, the ignition control
will go into a safety lockout and the valve will no
longer open until the control is reset. It may be
necessary to reset several times to bleed air out of
gas lines. To restart open and close loading door
and restart unit.

Table 2

If lockout condition persists, check that the manual
gas shut-off valve is in the ON position and that the
gas service is properly connected. If condition still
persists, remove tumbler from service.

8. Load the cylinder with a full load of clean rags

and run to remove oil or dirt from cylinder.

9. Check the airflow switch operation by opening

the lint panel. The heating systems should shut

off when the lint panel is opened a maximum of

1-1/2 inches (38 mm).
The airflow switch operation may be affected by

shipping tape still in place, lack of make-up air,

or an obstruction in the exhaust duct. These

should be checked and the required corrective

action taken before attempting to adjust the

airflow switch. To adjust the airflow switch refer

to Adjustments Section.

10. Wipe out the cylinder using an all-purpose

cleaner or detergent and water solution. Refer to
Figure 4

.

Figure 4

If the tumbler does not meet ANY of the above

requirements, remove tumbler from use. Refer to
Removing Tumbler from Service

Section.

Location

Prepurge

Time

(seconds)

Trial for
Ignition

(seconds)

Reset

Lockout

Condition

By:

Australia

18

5

Open loading

door

CE Marked

18

10

Press reset

button behind

front access

panel

All Others

(MT/CD)

1

15

Open loading

door

All Others

(OM)

1-3

10

Open loading

door

T452I

The tumbler must not be operated if the
airflow switch does not operate properly.
Faulty airflow switch operation may cause
an explosive gas mixture to collect in the
tumbler.

W072

WARNING

T452I