Installation

21

70256801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installing Gas Drying Tumblers in
the European Union (EU)

General Information

This information is to be used when installing gas

tumblers in countries and/or on gases different than the

machine’s factory configuration. Tumblers are

supplied from the factory for operaton on Natural Gas

or L.P. Gas in the countries of GB/IE/PT/ES/IT. To

install machines in any other country or on any other

gas requires some level of modification.

Models are built in three different configurations:

Regulated Natural Gas

– Injector is sized for

Natural Gas, second family, group H (E) at

20 mbar inlet pressure. Regulator/governor is

operational. Gas valve CAN be field-converted

to a non-regulating type.

Unregulated Natural Gas

– Injector is sized for

Natural Gas, second family, group E+ at

20.25 mbar inlet pressure. Regulator/governor is

blocked open. Gas valve CAN be field-converted

to a regulating type.

Unregulated L.P. (Liquified Petroleum) Gas

Injector is sized for L.P. Gas, third family, group

3+ at 28.37 mbar inlet pressure. Regulator/

governor is blocked open. Gas valve CAN be

field-converted to a regulating type.

Serial plates supplied from the factory are configured

for one of the three gases for the countries of GB/IE/

PT/ES/IT. This information pertains to situations when

the country of use or gas supply is different than that

on the serial plate.

Table 3

, Table 4 and Table 5 describe the different

gases that are available in different EU countries, and

how the machines need to be configured to operate

with those gases. In the EU, there are Natural Gases

that do not allow for machine regulation, and L.P.

Gases that must be regulated. For L.P. Gas, third

family B/P at 50 mbar, order Regulated Natural Gas

machines and convert according to tables.

WARNING

To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the

tumbler before servicing.

• Close gas shut-off valve to gas tumbler

before servicing.

• Close steam valve to steam tumbler

before servicing.

• Never start the tumbler with any guards/

panels removed.

• Whenever ground wires are removed

during servicing, these ground wires
must be reconnected to ensure that the
tumbler is properly grounded.

W002