Manifold venting, Figure 11 – Speed Queen Drying Tumblers none User Manual

Page 33

Advertising
background image

Exhaust Requirements

31

70256801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Manifold Venting

While it is preferable to exhaust tumblers individually

to the outdoors, a main collector duct may be used if it

is sized according to Figure 12. This illustration

indicates minimum diameters, and should be increased

if the collector length exceeds 14 feet (4.2 meters) and

two 90° elbows. The diameter of a round duct must be

increased by 10% for each additional 20 feet

(6.1 meters). Cross sectional area of a rectangular or

square duct must be increased 20% for each additional

20 feet (6.1 meters). Refer to Table 8 to determine

equivalent ducting sizing. The collector duct may be

rectangular or square in cross section, as long as the

area is not reduced. Provisions MUST be made for lint

removal and cleaning of the collector duct.
The vent collector system must be designed so the

static back pressure measured 12 inches (305 mm)

from the exhaust outlet does not exceed the maximum

allowable pressure specified on the installation sticker

on the rear of tumbler. Static back pressure must be

measured with all tumblers vented into the collector

operating.

Never connect a tumbler duct at a 90° angle to the
collector duct. Refer to Figure 11
. Doing so will
cause excessive back pressure, resulting in poor
performance. Never connect two tumbler exhaust
ducts directly across from each other at the point of
entry to the collector duct.

With the tumbler in operation, airflow at any point in

the duct should be at least 1200 feet per minute

(366 meters per minute) to ensure that lint remains

airborne. If 1200 feet per minute cannot be

maintained, schedule a regular inspection and cleaning

of the ductwork.
The collector system must be designed so the static

back pressure measured 12 inches (305 mm) from the

exhaust outlet does not exceed the maximum allowable

pressure specified on the installation sticker on the rear

of tumbler. This must be measured with all tumblers

vented into the collector operating.

Figure 11