High altitude orifice sizing, Table 10 – Speed Queen Drying Tumblers none User Manual

Page 39

Advertising
background image

Gas Requirements

37

70256801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

High Altitude Orifice Sizing

For proper operation at altitudes above 2000 feet

(610 meters), the gas orifice size must be reduced to

ensure complete combustion. Refer to Table 10 for

non-CE Marked models. (For CE Marked models,

consult local gas supplier.)

Table 10

Model

Gas

Altitude

Orifice

New Rate

feet

meters

No. inches

mm

Quantity Part Number

(Btu/hr)*

50EG

Natural Gas

2001-4000

610-1830

30

0.1285

3.3

2

M401021

87,400

4001-6000

1831-2440

31

0.1200

3.0

M401017

72,200

6001-10,000

2441-3050

32

0.1160

2.9

M402444

64,600

L.P. Gas

2001-4000

610-1220

47

0.0785

2.0

M400999

87,400

4001-6000

1221-1830

48

0.0760

1.9

M401001

79,800

6001-8000

1831-2440

49

0.0730

1.8

M401018

72,200

8001-10,000

2441-3050

50

0.0700

1.8

M401016

64,600

50CG

Natural Gas

2001-4000

610-1830

28

0.1405

3.6

2

M401014

110,400

4001-6000

1831-2440

29

0.1360

3.4

M400997

100,800

6001-10,000

2441-3050

30

0.1285

3.3

M401021

91,200

L.P. Gas

2001-4000

610-1220

44

0.0860

2.2

M401011

110,400

4001-6000

1221-1830

45

0.0820

2.1

M401027

100,800

6001-8000

1831-2440

46

0.0810

2.1

M401003

91,200

8001-10,000

2441-3050

47

0.0785

2.0

M400999

81,600

75CG

Natural Gas

2001-4000

610-1830

29

0.1360

3.4

3

M400997

151,800

4001-6000

1831-2440

30

0.1285

3.3

M401021

138,600

6001-10,000

2441-3050

31

0.1200

3.0

M401017

125,400

L.P. Gas

2001-4000

610-1220

45

0.0820

2.1

M401027

151,800

4001-6000

1221-1830

46

0.0810

2.1

M401003

138,600

6001-8000

1831-2440

47

0.0785

2.0

M400999

125,400

8001-10,000

2441-3050

48

0.0760

1.9

M401001

112,200

634

Natural Gas

2001-4000

610-1220

23

0.1540

3.9

3

M401020

197,800

4001-6000

1221-1830

25

0.1495

3.8

M402997

180,600

6001-8000

1831-2440

27

0.1440

3.7

M400998

163,400

8001-10,000

2441-3050

29

0.1360

3.4

M400997

146,200

L.P. Gas

2001-4000

610-1220

42

0.0935

2.4

M403017

197,800

4001-6000

1221-1830

43

0.0890

2.3

M406184

180,600

6001-8000

1831-2440

44

0.0860

2.2

M401011

163,400

8001-10,000

2441-3050

45

0.0820

2.1

M401027

146,200

* Btu/hr derate of 4% per 1000 feet (305 meters) of altitude.