Airflow switch, Warning – Speed Queen Drying Tumblers none User Manual

Page 49

Advertising
background image

Adjustments

47

70256801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Airflow Switch

Gas and Electric Tumblers

The airflow switch (located on the rear of tumbler,
Figure 19

) is set at the factory for proper operation.

However, if there is a problem with the switch, it

should be adjusted as follows:

NOTE: Steam models do not have an airflow switch.

NOTE: Control panel must be in place and access
door closed before attempting to adjust airflow switch.

IMPORTANT: Airflow switch disc must remain
closed during operation. If it opens and closes
during the drying cycle, this indicates insufficient
airflow through the tumbler. If switch remains
open, or pops open and closed during the cycle, the
heating system will shut off. The cylinder and fan
will continue to operate even though the airflow
switch is opened.

The airflow switch operation is controlled by the

counterweight position in the shaft. Moving the

counterweight either increases or decreases airflow

switch sensitivity. The counterweight should be

adjusted so the disc moves away from the cabinet

when the lint panel is opened 1.5 inches (38.1 mm) with

a full load. Adjust the airflow switch as follows:

1. Load the tumbler. This adjustment is much faster

to make with one person opening lint panel in

front and another adjusting the counterweight in

the rear of tumbler.

2. Start the tumbler. Open the lint panel 1.5 inches

(38.1 mm). The airflow disc should move away

from the cabinet, opening the switch contacts and

shutting off the heat system. This indicates

proper operation and proper adjustment.

3. If switch is not opening as described in step 2, it

should be adjusted so it is MORE sensitive.

Depress the spring clip and move counterweight

toward disc. Retest by opening lint panel and

continue moving counterweight toward disc until

switch operates as described in step 2.

4. If switch opens BEFORE lint panel is opened the

proper distance, step 2, it should be adjusted so it

is LESS sensitive. Depress the spring clip and

move counterweight away from the disc. Retest

by opening lint panel and continue moving

counterweight away from disc until switch

operates as described in step 2.

WARNING

To reduce the risk of fire, airflow switch
operation may be affected by a clogged
lint screen, lack of make-up air,
obstructions in the vertical recirculation
stack or in the customer installed main or
collector ducts. These conditions must be
checked and necessary corrections
made before adjusting airflow switch.
Always adjust airflow at installation.

W073