The following steps outline the procedure for

connecting the electrical service to the tumbler.

NOTE: The wiring diagram is supplied in
literature packet in cylinder.

1. Install a circuit breaker as close to the tumbler as

possible. If more than one tumbler is being

installed, a disconnect switch or circuit breaker

should be provided for each. This will make it

possible to disconnect each tumbler for

maintenance purposes.

2. Connect the conduit-encased leads to the disconnect

switch, or circuit breaker. Connect the wire leads

to the appropriate labeled terminal on the terminal

block. The ground wire must be connected to the

ground connection as shown in Figure 16.

3. Check the electrical service phase sequence

(three phase only) as follows:

a. Energize the electrical service (on reversing

tumblers, ensure nonreversing is selected) and

momentarily start the tumbler. Check the

direction of the cylinder rotation. If the

cylinder rotates clockwise (viewed from the

front), the phase sequence is correct. If the

cylinder rotates counterclockwise, proceed

with step b.

NOTE: On reversing tumblers, the fan
motor should also rotate clockwise (viewed
from the front) on all models except the
F75 models which rotate counterclockwise
(viewed from the front).

b. Disconnect and reverse any two service leads

on the terminal block.