AI232 Version 9.6x User’s Guide

AI232 Commands: alarm

8-20

alarm

Description

This command:

z

Displays a list of the alarm groups and the overall alarm severity

z

Displays alarms for a specified alarm group or for a specified range of severity
levels within an alarm group

z

Displays alarms by severity level or for a specified range of severity levels

z

Clears all non-self-clearing alarm groups and the overall alarm severity

z

Clears a specified non-self-clearing alarm group

z

Masks a specified alarm group

z

Unmasks a specified alarm group.

Command Type

shell

Formats

alarm [

group

[

range

] ]

alarm -sev [

range

]

alarm { -clear [

group

] | -mask

group

| -unmask

group

}

Parameters

group

Defines the group of alarms to display, clear, mask, or unmask. Valid
values are existing alarm groups.

range

Defines a range of alarm severity levels to display. Valid values are

1

to

32

. Individual values in the range are separated by hyphens (

-

).

-sev

Displays all alarms or a range of alarms based severity level.

-clear

Clears all non-self-clearing alarm groups or a specified non-self-clearing
alarm group.



Note: Only non-self-clearing alarm groups can be manually cleared.

Self-clearing alarms clear themselves when the problem that
caused the alarm is resolved.

-mask

Prevents a specified alarm group from affecting overall alarm severity.

-unmask

Allows a specified alarm group to affect overall alarm severity.