AI232 Version 9.6x User’s Guide

AI232 Commands: staslc

8-93

Examples

This example displays the link and cable status information for links

1

to

5

.



Note: Not all links are displayed here. Entering the command with no additional

parameters would show all 32 links.

[232]staslc 1-5

Link Status Appl. DTR RTS CTS DSR DCD Format Parity Frame Overun Underun
1: Idle Login + + - - - 9600,8,n,1 0 0 0 0
2: Disabled Login ? ? ? ? ? 9600,8,n,1 0 0 0 0
3: -MMUX ? ? ? ? ? 19200 0 0 0 0
4: Disabled Login ? ? ? ? ? 9600,8,n,1 0 0 0 0

5: Disabled Login ? ? ? ? ? 9600,8,n,1 0 0 0 0
DP232 Cable Status: Ports 1-8 Connected Ports 9-16 Not Connected
Ports 17-24 Not Connected Ports 25-32 Not Connected

[232]

Column

Description

Link

Displays the number of the link.

Status

Displays the link status as

dataxfer

(data is being transfered),

idle

, or

disabled

.

Appl.

Displays the application specified for the link (

Alias

,

Login

, or

Destination

).

DTR RTS CTS DSR DCD

Displays the status of the control signals. (

+

means the signal

is asserted and

-

means the signal is negated.)

Format

Displays the baud rate, number of data bits, parity (

none

,

odd

,

or

even

), and number of stop bits specified for the link.

Parity

Displays the number of parity errors.

Frame

Displays the number of framing errors.

Overun

Displays the number of overrun errors.

Underun

Displays the number of underrun errors.