MC-12

Setup

3-47

PERFORMING AUTOMATIC CALIBRATION

Follow the procedures in the appropriate table column for the desired type of automatic calibration.

STEP

DISTANCES

DISTANCES & LEVELS

LEVELS

1

2

AUTO SPEAKER SETUP

SPEAKER SETUP

SET CROSSOVERS
CHECK MICROPHONES
AUTOMATIC
MANUAL

CUSTOM SETUP

40 Hz
60 Hz
60 Hz
60 Hz
40 Hz

OFF

N/A

APART

AUTO SPEAKER SETUP

DISTANCES & LEVELS

SET CROSSOVERS

BEFORE CALIBRATING

MAIN MENU

MODE ADJUST
AUDIO CONTROLS
SETUP

DISTANCES
OUTPUT LEVELS

PLACE MICROPHONES

IN PRIMARY LISTENING

POSITIONS

CUSTOM SETUP

40 Hz
60 Hz
60 Hz
60 Hz
40 Hz

OFF

N/A

APART

AUTO SPEAKER SETUP

!CAUTION!

HIGH AUDIO LEVELS

TEST WILL BEGIN IN

10

YOU WILL HAVE 10 SEC

TO LEAVE THE ROOM OR

SIT QUIETLY

PRESS TO BEGIN

COUNTDOWN

PRESS TO SKIP

COUNTDOWN

SETUP

INPUTS
SPEAKERS
REAR PANEL CONFIG
DISPLAYS
VOLUME CONTROLS
TRIGGERS
LOCK OPTIONS
LIVE! CALIBRATION

Select the SPEAKER SETUP menu AUTOMATIC option as shown in the menu illustration above.

• If a microphone check is successful, the AUTO SPEAKER SETUP menu becomes available on the on-screen display. Press

the

or

arrow button to highlight the automatic calibration option you want. Then, press the

arrow button to select

this option. Refer to the table on page 3-35 for more information about automatic calibration options.

• If a microphone check is unsuccessful, one of the error messages shown at the right appears on the on-screen display, indicat-

ing that a successful microphone check is required before automatic calibration is available, and also the reason the previous
check failed. If this occurs, go back to “Connecting the Microphones” on page 3-36 and work your way forward to this page.

MIC CHECK REQUIRED

FOR AUTO CALIBRATION

NO MICROPHONE

DETECTED

The following AUTO SPEAKER SETUP messages display on-screen before automatic calibration begins:

• The !CAUTION! HIGH AUDIO LEVELS message indicates that the MC-12 generates loud calibration noise signals during automatic calibration. If the

signals become too loud, press the

arrow button to cancel automatic calibration. Press the

arrow button to open the next AUTO SPEAKER

SETUP menu.

• The countdown display notifies you that automatic calibration will begin in 10 seconds. The primary reason for the 10 second delay is to give you time

to leave the listening space before automatic calibration begins. If you choose to remain in the room, your movements could affect the calibration
results. If you leave the room, you can return in about 10 minutes (the calibration procedure should be completed). Press the

arrow button to

skip the countdown and begin automatic calibration. The MC-12 automatically activates automatic calibration when the countdown ends.