Alarm code: 2, Event id: ela-delivts02, Alarm code: 3 – Lucent Technologies INTUITY Messaging Solutions Enhanced-List Application 585-310-575 User Manual

Page 70: Event id: ela-delivts03, Alarm code: 4, Event id: ela-delivts04

Advertising
background image

Alarms

60

Issue 1 July 1997

Alarm Code: 2

Event ID: ELA-delivts02

Alarm Level:

Warning

Description:

Trusted-server data partially lost, re-enter or restore.

Repair Action:

There are two recovery methods:

Access the Set Up Enhanced-List System Data window and re-enter all
field information.

Restore data from the most recent backup of system data. See Chapter 3,
“Common System Procedures,” in your maintenance book for instructions
about restoring data. If you would prefer to have assistance with this
restore, contact your remote maintenance center.

Alarm Code: 3

Event ID: ELA-delivts03

Alarm Level:

Warning

Description:

Trusted-server data corrupt, re-enter or restore.

Repair Action:

There are two recovery methods:

Access the Set Up Enhanced-List System Data window and re-enter all
field information.

Restore data from the most recent backup of system data. See Chapter 3,
“Common System Procedures,” in your maintenance book for instructions
about restoring data. If you would prefer to have assistance with this
restore, contact your remote maintenance center.

Alarm Code: 4

Event ID: ELA-delivts04

Alarm Level:

Warning

Description:

Trusted-server data no longer valid.

Repair Action:

1. In AUDIX, enter

ch tr

administrative_trusted_server_name.

Advertising