Alarms

68

Issue 1 July 1997

2. Verify that the shadow mailbox belongs to a community that cannot

receive messages.

NOTE:

The sending restrictions must be identical on all machines in the
I

NTUITY

AUDIX network. Check the sending restrictions on all

machines.

See

Lucent I

NTUITY

Messaging Solutions Release 4 Administration,

585-310-564 for more detailed procedures.

Event ID: ELA-shadow07

Description:

Shadow mailbox space gridlock caused no ELA service for

longer than number hours.

Repair Procedure:

See the procedure for SHADOW Resource Type, "Alarm Code: 6" on page 6-64.

Event ID: ELA-delivts05

Description:

Number minutes with session resources unavailable for

delivery trusted server.

The trusted server that delivers ELA messages cannot access
AUDIX. The message shows the amount of elapsed time (in 30
minute increments) since ELA has stopped providing service.

When the time elapsed exceeds the value in the

Minutes of

Inactivity Before Alarm:

field on the Trusted-Server Profile

screen, AUDIX generates a minor alarm (event ID: SERVER0900,
resource type SERVER, alarm code 900.)

Repair Procedure:

1. Open the System Parameters IMAPI-Options screen.

2. Is the value in the

Simultaneous Sessions Available for

Trusted Server Access:

field at least 2?

If yes, go to step 3.

If no, change the value.

3. Determine if the AUDIX server is so overloaded that it has no resources

available for ELA. Some questions to ask are:

How many trusted servers are on the network?

What are their activity cycles?