CONTROL CABLE CONNECTION:

Digital Control Cable: Figure A.3

Power Source

A

A

B

B C

C

D

D

E

E

Wire Feeder

A

A

B

B

C

C

D

D

E

E

Power Source

Pin

Function

A

Digital I/O

B

Digital I/O

C

"67" voltage sense

D

40 VDC

E

Common

Wire Feeder

Pin

Function

A

Digital I/O

B

Digital I/O

C

"67" voltage sense

D

40 VDC

E

Common

A

A

B

B

C

C

D

D

E

E

A

A

B

B

C

C

D

D

E

E

A

A

B

B

C

C

D

D

FF

E

E

A

A

B

B

G

G

C

C

D

D

FF

E

E

Function

5 pin trigger con-
nector for push-
only guns.

6 pin connector for
remote control or
foot/hand amptrol.

7 pin connector for
push-pull guns

Function

5 pin ArcLink con-
nector.

PIN

A
B
C
D
E

A
B
C
D
E
F

A
B
C
D
E
F

G

PIN

A
B
C
D
E

Wiring

Trigger

Not used

Trigger, Common

Dual Procedure Selection

Dual, Common

77 Remote potentiometer, 5K

75 Remote potentiometer, common

76 Remote potentiometer, wiper

Switch, On/Off

Switch, common

Not used

Motor -

Motor +

77 Remote potentiometer, 5K

76 Remote potentiometer, wiper

Switch, On/Off

Switch, common

75 Remote potentiometer, common

Wiring

ArcLink
ArcLink

67 Electrode Voltage Sense

40VDC

40VDC, Common

CABLE CONNECTIONS

There are three circular connectors on the front of the
POWER FEED® 25M.

There is one circular connector on the rear of the POWER FEED® 25M.

DIGITAL CONTROL CABLE, K1543-XX

(See Figure A.3)
ArcLink/LincNet control cables are special high quality
cables for digital communication. The cables are cop-
per 5 conductor cable in a SO-type rubber jacket.
There is one 20 gauge twisted pair for network com-
munications. This pair has an impedance of approxi-
mately 120 ohms and a propagation delay per foot of
less than 2.1 nanoseconds. There are two 12 gauge
conductors that are used to supply 40VDC to the net-
work. The fifth wire is 18 gauge and is used as an elec-
trode sense lead.

Use of non-standard cables may lead to system shut-
downs, poor arc starting and wire feeding problems.

The control cables connect the power source to the
wire feeder, and the wire feeder to other wire feeders.

Control cables may be connected end to end to extend
their length. Use a maximum of 200 ft. (61.0m) of con-
trol cable between components.