Troubleshooting and repair, Caution – Lincoln Electric POWER FEED SVM185-A User Manual

Page 83

Advertising
background image

FUNCTION PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

The purge switch does not activate
the gas solenoid, but gun trigger
closure in the MIG or pulse modes
does activate the solenoid. The
LEDs are steady green on the
power source, and wire drive unit.

1. Make certain the COLD

INCH/GAS PURGE switch is
operating properly.

2. Check for loose or faulty leeds

between COLD INCH/GAS
PURGE switch and the feedhead
board. See wiring diagram.

1. If the COLD INCH/GAS PURGE

switch is operating correctly and
the associated leeds are OK.
The feedhead board may be
faulty.

The COLD INCH/GAS PURGE
switch does not turn on the wire
drive motor but gun trigger closure
in the MIG or Pulse modes does
activate the wire drive motor.
The LEDs are steady green on the
power source, and wire drive unit.

1. Make certain the COLD

INCH/GAS PURGE switch is
operating properly.

2. Check for loose or faulty leeds

between the COLD INCH/GAS
PURGE switch and the feedhead
board. See wiring diagram.

1. If the COLD INCH/GAS PURGE

switch is operating correctly and
the associated leads are OK.
The feedhead board may be
faulty.

The voltmeter on the wire feeder
does not function properly even
though the STATUS LEDS are
steady green.

1. Make sure the DIP switches are

configured correctly for the weld-
ing polarity being used. See
Setting Dip Switches in the Wire
Drive
in the Installation section
of this manual.

2. Check the #67 lead on the wire

drive unit. Make sure it is connect-
ed to the motor gear box and also
the voltage sense PC board.

3.Check the work sensing leads on

the POWER FEED® 25M power
source. Check leads #202 (Neg.
output terminal) and #206 (pos.
output terminal). See POWER
FEED® 25M wiring diagram. If
external voltage sensing is utilized,
Check the #21 lead between the 4-
pin receptacle on the front of the
POWERWAVE® and the work-
place.

1. Check leads #513 and #514 from

J85 on the feedhead board to the
voltage sense PC board. Verify
placement in proper cavities.

2. Perform the Voltage Sense

Board Test.

3. The display board may be faulty.

4. The feedhead control board may

be faulty.

5. The Control Box control board

may be faulty.

TROUBLESHOOTING AND REPAIR

F-9

F-9

POWER FEED® 25M

Retur

n

to

Section

T

OC

Retur

n

to

Section

T

OC

Retur

n

to

Section

T

OC

Retur

n

to

Section

T

OC

Retur

n

to

Master

T

OC

Retur

n

to

Master

T

OC

Retur

n

to

Master

T

OC

Retur

n

to

Master

T

OC

Advertising