GMAW-STT™

Waveform Control Technology™

maximizes the

ability to modify the arc for the perfect weld. When

STT™

welding, the parameters to control are:

• Wire Feed Speed - sets the deposition rate.
• Peak Current - controls the arc length.
• Background Current - regulates the bead contour.
• Tail-out - provides additional power in the arc.

There is no Voltage control when

STT™

welding.

220

----

WFS AMPS

VOLTS TRIM

Less

Deposition

More

Deposition

EFFECT / RANGE

PEAK CURRENT

B A C K G R O U N D

CURRENT

TAIL OUT

( STT ll MODES

ONLY)

DESCRIPTION

Peak Current acts similar to an arc pinch

control. Peak Current sets the arc length
and promotes

-

g o o d f u s i o n . H i g h e r peak

current levels will cause the arc to broaden
momentarily while increasing arc length. I f
set too high, globular transfer may occur.
Setting it too low may cause instability
and wire stubbing. Best practice is to

adjust for minimum spatter and puddle

agitation.

Background Current controls the overall

heat input in the weld.

Tail out provides additional p o w e r

w i t h o u t t h e m o l t e n droplet becoming

too large. Increase as necessary to add
heat input without increasing arc length.

Often this results in faster travel speeds.

Note that as tail out increases, the peak
current

to be reduced.

and/or background current may need

PREFLOW TIME

0 - 10 seconds

RUN-IN WFS:

Off, 50 to150 in/min.

Start Procedure

FUNCTION

Adjusts the time that shielding

gas flows after the trigger is

pulled and prior to feeding wire.

R u n - i n s e t s t h e w i r e f e e d

speed from the time the trigger

is pulled until an arc is estab-

lished.

The Start Procedure is not

commonly used with STT

procedures.

PARAMETER

RANGE

Postflow Time:

0 to 10 seconds

FUNCTION

Adjusts the time that shielding

gas flows after the welding out-

put turns off.

ELECTRODE AND GAS

STEEL CO

2

STAINLESS

Ar/CO

2

He/Ar/CO

2

STEEL CO

2

STAINLESS

Ar/CO

2

He/Ar/CO

2

WIRE SIZE

0.035 0.045 0.052

110 126 126
110 126 126

WELD MODES

START OPTIONS

END OPTIONS

ARC CONTROL

Steel

.035"

SET

SETUP

IR PORT

STT

WAVEFORM CONTROL TECHNOLOGY

WELD MODE

ARC CONTROL

109

START OPTIONS

END OPTIONS

STEEL CO

STEEL CO

STEEL AR/CO

STAINLESS He/Ar/CO

STAINLESS He/Ar/CO

STAINLESS Ar/CO

2

2

2

2

2

2

(with Hot Start)

(SYNERGIC STT)

SYNERGIC STT, OPEN ROOT

123 124 124
123 124 124

111 117 120
112 118 121

113 119 122
135 137 ---

127 129 ---
131 133 ---

Burnback: 0 to .25

Seconds

T h e b u r n b a c k t i m e i s t h e

amount of time that the weld

output continues after the wire

stops feeding. It prevents the

wire from sticking in the puddle

and prepares the end of the

wire for the next arc start.

Crater Procedur e

Crater is not commonly used

in STT weld procedures.

MSP4 OPERATION