Four items show on the MSP4 panel.

• Memory Value
• High Limit
• Low Limit
• Parameter Name

One of these items will flash to indicate which item will
change when the MSP4 encoder is rotated. Press the
right button on the MSP4 panel to select the item to
change.

The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory cho-
sen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.

To lock a parameter to a specific value that cannot
be changed, set the high and low limits to the same
value.

SET

SETUP

Hi

Hi

Lo

Lo

IR PORT

Weld WFS

= 200

= 180

WAVEFORM CONTROL TECHNOLOGY

WELD MODE

ARC CONTROL

START OPTIONS

END OPTIONS

200

SET

SETUP

Hi

Hi

Lo

Lo

IR PORT

Weld WFS

= 200

= 180

WAVEFORM CONTROL TECHNOLOGY

WELD MODE

ARC CONTROL

START OPTIONS

END OPTIONS

200

Memory Value

Parameter Name

High Limit

Low Limit

The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.

After setting limits, press the memory button with the
flashing LED. The MSP4 will ask to save or discard the
limit changes just made. Press the left MSP4 for but-
ton (YES) to save and enable the limits and exit. Press
the right MSP4 button (NO) to exit and leave limits
unchanged.

Enabling/Disabling Limits

Limits for each memory may be enabled or disabled
by pressing and hold the appropriate memory button
for 10 seconds. Release the memory button when
the MSP4 display shows the following:

Press the left MSP4 button (YES) to enable limits or
the right MSP4 button (NO) to disable limits. Disabling
limits does not change any limits values that may
have been previously set.

HOLD 2 SECONDS TO SAVE

PROCEDURE

MEMORY

A

GUN

B

1

4

2

5

3

6

M

M

Enable/Disable

Limits: Press

10 seconds

Rotate to

Change

Value.

Press to

select item

to change.

SET

SETUP

IR PORT

Enable/Disable

Memory 1
Limits

WAVEFORM CONTROL TECHNOLOGY

WELD MODE

ARC CONTROL

START OPTIONS

END OPTIONS

SET

SETUP

IR PORT

Yes

No

Enable
Limits?

WAVEFORM CONTROL TECHNOLOGY

WELD MODE

ARC CONTROL

START OPTIONS

END OPTIONS