No shielding gas, Troubleshooting and repair, Caution – Lincoln Electric POWER FEED SVM185-A User Manual

Page 80

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

The feeder does power up - no dis-
play, no cold feed.

1. The POWER FEED® 25M power

switch is OFF.

2. The Power Wave power source is

OFF.

3. The circuit breaker for the wire

feeder on power source have
tripped.

4. The control cable may be loose or

damaged.

5. The power switch is damaged.

1. Turn the POWER FEED® 25M

power switch ON.

2. Turn ON the Power Wave power

source.

3. Reset the circuit breakers.
4. Tighten, repair or replace the

control cable.

5. Replace the power switch.

No shielding gas.

1. The gas supply is OFF or empty.
2. The gas hose is cut or crushed.
3. Dirt or debris is in the solenoid.
4. There is a loose solenoid connec-

tion or the solenoid has failed.

1. Verify the gas supply is ON and

flowing.

2. Route the gas hose so it avoids

sharp corners and make sure
nothing is on top of it. Repair or
replace damaged hoses.

3. Apply filtered shop at 80psi to the

solenoid to remove dirt.

4. Remove the cover and check

that all connections are in good
condition.

Inconsistent wire feeding or wire
not feeding but drive rolls turning.

1. The gun cable is kinked and/or

twisted

2. The wire is jammed in the gun and

cable.

3. The gun liner is dirty or worn.
4. The electrode is rusty or dirty.
5. The contact tip is partially melted

or has spatter.

6. Improper gun liner, tip, drive rolls

and/or inner wire guide.

7. Incorrect tension arm pressure on

the drive rolls.

8. Worn drive roll.

1. Keep the gun cable as straight as

possible. Avoid sharp corners or
bends in the cable.

2. Remove the gun from the wire

feeder and pull the jammed wire
out of the gun and cable.

3. Blow dirt out of the liner with low

pressure (40psi or less). Replace
the liner if worn.

4. Use only clean electrode. Use

quality electrode, like L-50 or L-56
from Lincoln Electric.

5. Replace the contact tip.
6. Verify the proper parts are

installed.

7. Adjust the tension arm per the

Instruction Manual. Most elec-
trodes feed well at a tension arm
setting of "3".

8. Replace the drive rolls if worn or

filled with dirt.

TROUBLESHOOTING AND REPAIR

F-6

F-6

POWER FEED® 25M

Retur

n

to

Section

T