WELD CABLE SIZE

Table A.1 located below are copper cable sizes recom-
mended for different currents and duty cycles. Lengths
stipulated are the distance from the welder to work and
back to the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable drop.

COAXIAL WELD CABLE

Coaxial welding cables are specially designed welding
cables for pulse welding or STT™ welding. Coaxial weld
cables feature low inductance, allowing fast changes in
the weld current. Regular cables have a higher inductance
which may distort the pulse or STT™ wave shape.
Inductance becomes more severe as the weld cables
become longer.

Coaxial weld cables are recommended for all pulse and
STT™ welding, especially when the total weld cable
length (electrode cable + work cable) exceeds 50 feet
(7.6m).

A coaxial weld cable is constructed with multiple small
leads wrapped around one large lead. The large inner
lead connects to the electrode stud on the power source
and the electrode connection on the wire feeder. The
small leads combine together to form the work lead, one
end attached to the power source and the other end to the
work piece. See Figure A.5

EElleecctrtrooddee

W

Woorrkk

W

Woorrkk

Electrode

Electrode

W

Work

ork

Electrode

Electrode

W

Work

ork

Power Source

Power Source

Coaxial W

Coaxial Weld Cable

eld Cable

Wire Feeder

Wire Feeder

** Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables

larger than recommended, or cables rated higher than 167°F(75°C).

RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 167°F or 75°C)**

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES

AMPERES

200
200
225
225
250
250
250
250
300
325
350
400
400
500

PERCENT

DUTY

CYCLE

60

100

20

40 & 30

30
40
60

100

60

100

60
60

100

60

0 to 50Ft.
(0 to15M)

2
2

4 or 5

3
3
2
1
1
1

2/0
1/0
2/0
3/0
2/0

50 to 100Ft.

(15 to 30M)

2
2
3
3
3
2
1
1
1

2/0
1/0
2/0
3/0
2/0

100 to 150 Ft.

(30 to 46M)

2
2
2
2
2
1
1
1
1

2/0
2/0
2/0
3/0
3/0

150 to 200 Ft.

(46 to 61M)

1
1
1
1
1
1
1
1

1/0
2/0
2/0
3/0
3/0
3/0

200 to 250 Ft.

(61 to 76M)

1/0
1/0
1/0
1/0
1/0
1/0
1/0
1/0
2/0
3/0
3/0
4/0
4/0
4/0

TABLE A.1

FIGURE A.5