EXAMPLE 1 - 2 STEP TRIGGER:

Simple operation

The simplest trigger operation occurs with a 2 Step
trigger and the Start, Crater and Burnback functions all
set to OFF. (See Figure B.19)

For this sequence,

PREFLOW:

Shielding gas begins to flow immediately when the gun
trigger is pulled.

STRIKE:

After preflow time expires, the power source regulates
to the welding output and wire is advanced towards the
work piece at the strike Run-In WFS. If an arc is not
established within 1.5 seconds, the wire feed speed
will jump to the welding wire feed speed.

WELD:

The power source output and the wire feed speed con-
tinue at the weld settings for as long as the trigger is
pulled.

POSTFLOW:

As soon as the trigger is released, the

power source output and the wire feed speed are
turned OFF. Shielding gas continues until the post
flow timer expires.

Shielding

Gas

Idle

Preflow

Strike

Weld

Postflow

Idle

Power

Source

Output

WFS

On

Off

Run-in

Off

Weld

Off

Weld

Ar

c

Es

ta

bl

ish

ed

Tr

ig

ge

r P

ul

le

d

Tr

ig

ge

r R

el

ea

se

d

2 Step Trigger

Start = OFF

Crater = OFF

Burnback = OFF

1.5 sec max.

FIGURE B.19

Advertising