CONSTANT VOLTAGE OUTPUT

The controlled DC output from the SCR rectifier
assembly is supplied to the power factor enhancement
choke which limits the rate at which the supply current
rises through the capacitors. The DC output from the

NOTE: Unshaded areas of Block Logic

Diagram are the subject of discussion

FIGURE E.4 — CONSTANT VOLTAGE OUTPUT.

LINE

SWITCH

RECONNECT

MAIN

TRANSFORMER

SNUBBER

BOARD

RECTIFIER

DIODE

BRIDGE

ARC

VOLTAGE

WIRE

SPEED

GAS

SOLENOID

FAN

MOTOR

CONTROL

BOARD

WIRE

DRIVE

MOTOR

TACH

GUN TRIGGER

FEEDBACK

115 VAC

30 VAC

G

A
T
E

S

I

G
N

A

L

SCR

RECTIFIER

POWER

ENHANCEMENT

CHOKE

OUTPUT

CHOKE

C
A
P
A
C

I

T

O
R

S

F
E
E

D
B
A
C
K

NEGATIVE
TERMINAL

POSITIVE

TERMINAL

SHUNT

power factor enhancement choke is filtered by the
capacitor bank resulting in a constant voltage DC out-
put. Since the output choke is in series with the posi-
tive leg of the rectifier and also in series with the gun
and welding load, a filtered constant voltage output is
applied to the output terminals of the machine.