9. Make the following voltage test:

a. Turn the machine OFF between

each test.

b. Carefully connect the meter probes

to the exposed lead connections.

c. Turn the machine ON to conduct

the voltage test.

10. If the DC voltage tested is incorrect or

missing, and the AC voltages are cor-
rect, the rectifier diode bridge may be
faulty.

6. Turn the POWER MIG 255 ON/OFF

POWER SWITCH to ON.

7. Carefully make the following voltage

tests:

a. Turn the machine OFF between

each test.

b. Carefully connect the meter plugs

to the exposed lead connections.

c. Turn the machine ON to conduct

the voltage test.

8. If any of the AC voltages tested are

incorrect or missing, check the M19248
snubber PC board and associated
leads and connections. See the wiring
diagram.

RECTIFIER DIODE BRIDGE TESTING (continued)

FROM

LEAD

208R

209R

TO

LEAD

206

206

EXPECTED

VOLTAGE

28 VAC

28 VAC

FROM

LEAD

354

TO

LEAD

206

EXPECTED

VOLTAGE

36 VDC

Advertising