TROUBLESHOOTING & REPAIR

4. Locate plug J5 and plug J6 on the

G3521 control PC board, and J9 on the
M19248 snubber PC board. See Figure
F.1.

NOTE:

The location of plugs may vary

depending on the machine code.

5. Locate the following leads on plug J6

on the G3521 control PC board:

TEST PROCEDURE

The ON/OFF POWER SWITCH will be
“hot” during these tests.

----------------------------------------------------------

NOTE:

Secondary voltages will vary pro-

portionately with the primary input voltage.

1. Disconnect the main input power sup-

ply to the machine.

2. Remove the case top and side panels

with a 3/8 in. nutdriver.

3. Remove the tool tray with a 5/16 in. nut-

driver.

FIGURE F.1 — G3521 CONTROL PC BOARD AND M19248 SNUBBER PC BOARD

MAIN TRANSFORMER TEST POINTS.

J6

J5

J3

J8

J1

J4

J2

J9

X8

(16J5)

X9

(8J5)

#206

(3J5)

#208S

(2J9)

#209S

(6J9)

X7

(4J6)

X6

(5J6)

X5

(6J6)

MAIN TRANSFORMER TEST (continued)

WARNING

PLUG

LOCATION

6J6
5J6
4J6

LEAD

X5
X6
X7

Advertising