Troubleshooting & repair – Lincoln Electric POWER MIG 255 SVM144-B User Manual

Page 67

Advertising
background image

POWER MIG 255

TROUBLESHOOTING & REPAIR

F-29

F-29

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

2. Locate plug J1 on the G3521 control

PC board. See Figure F.9.

3. Locate the following leads on Plug J1:

4. Connect main input power to the

machine.

5. Make the following voltage tests:

a. Turn the machine OFF between

each test.

b. Carefully insert the meter probes

into the back of each Molex plug
pin cavity.

6. If the 15 VDC is present, check the

leads to the tachometer circuit.

7. If the leads are okay and 15 VDC is

present, the correct voltage is being
received from the control PC board,
continue with the Supply Voltage to
Tachometer Test.

8. If the 15 VDC is not present and the

leads are okay, the control PC board
may be faulty, replace the control PC
board.

6. Make the following voltage tests:

a. Turn the machine OFF between

each test.

b. Carefully insert the meter probes

into the back of each Molex plug
pin cavity to perform the test.

c. Turn the machine ON and pull the

gun trigger to conduct the voltage
test.

7. If the voltage to the wire drive motor

armature is zero, check the wires
between plug J1 and the wire drive
motor. Also check the electrical connec-
tor J12 for proper connection and con-
tact.

8. If all wires and connectors are good and

the voltage to the drive motor armature
is zero, the G3521 control PC board
may be faulty, replace the control PC
board.

9. If the motor is running at high speed

and the armature voltage is high and
uncontrollable, proceed with the
tachometer test.

TEST FOR SUPPLY VOLTAGE
TO TACHOMETER

1. Disconnect the main AC input power to

the machine.

WIRE DRIVE MOTOR AND TACHOMETER FEEDBACK TEST (continued)

FROM

LEAD

B

(4J1)

TO

LEAD

W

(2J1)

EXPECTED

VOLTAGE

3-20 VDC

(varies depend-

ing on wire feed

speed)

FROM

LEAD

515B

(5J1)

TO

LEAD

206B

(1J1)

EXPECTED

VOLTAGE

15 VDC

PLUG

LOCATION

5J1
1J1

LEAD

515B
206B