Perform the scr rectifier assembly tests, Troubleshooting & repair, Warning – Lincoln Electric POWER MIG 255 SVM144-B User Manual

Page 57

Advertising
background image

POWER MIG 255

TROUBLESHOOTING & REPAIR

F-19

F-19

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

STATIC SCR RECTIFIER ASSEMBLY TEST

Service and repair should only be performed by Lincoln Electric factory trained
personnel. Unauthorized repairs performed on this equipment may result in dan-
ger to the technician or machine operator and will invalidate your factory war-
ranty. For your safety and to avoid electrical shock, please observe all safety
notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per-
form the test/repairs safely, contact the Lincoln Electric service department for
technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

-------------------------------------------------------------------------------------------------------------------

TEST DESCRIPTION

This test is used to quickly determine if an SCR or diode is shorted or “leaky.” See the
Machine Waveform Section in this manual for normal and abnormal output waveforms.

MATERIALS NEEDED

Analog Volt-ohmmeter
POWER MIG 255 wiring diagrams (See Electrical Diagrams Section of this Manual)
3/8 in. Nutdriver
5/16 in. Nutdriver
1/2 in. Open end or socket wrench

WARNING

Advertising