Troubleshooting and repair – Lincoln Electric POWER MIG 255 SVM144-B User Manual

Page 52

Advertising
background image

POWER MIG 255

TROUBLESHOOTING AND REPAIR

F-14

F-14

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

c. If any of the voltages tested are

incorrect, check for loose or broken
leads between the test points and
the main transformer.

d. If ALL the voltages tested are incor-

rect or missing, go to step 16.

17. Test for correct nameplate input

voltage between the H1 lead at the
ON/OFF POWER SWITCH to H2 or
H3 (H5 if connected for 575 VAC) at
the reconnect panel. Voltage tested will
vary depending on input voltage
connection. See wiring diagram for test
point locations.

a. If the voltage test is incorrect,

-check for loose or broken leads
between the reconnect panel and
the ON/OFF POWER SWITCH.

-test the ON/OFF POWER
SWITCH for proper operation.

b. If the correct nameplate voltage is

being applied to the main trans-
former and one or more of the sec-
ondary voltages are missing or are
incorrect, the main transformer may
be faulty. Replace.

14. Locate the following leads on plug J9

on the M19248 snubber PC board and
on plug J5 on the G3521 control PC
board. See Figure F.1.
G3521:

M19248:

15. Turn the machine ON.

16. Make the following voltage tests at plug

J9 on the M19248 snubber PC board
and at plug J5 on the G3521 control PC
board.

a. Turn the machine OFF between

each test.

b. Carefully insert the meter probes

into the back of each Molex plug
pin cavity to perform the test.

MAIN TRANSFORMER TEST (continued)

PLUG

LOCATION

3J5

LEAD

206

PLUG

LOCATION

2J9
6J9

LEAD

208S
209S

FROM

LEAD

208S

(2J9 on

M19248)

208S

(2J9 on

M19248)

209S

(6J9 on

M19248)

TO

LEAD

209S

(6J9 on

M19248)

206

(3J5 on
G3521)

206

(3J5 on
G3521)

EXPECTED

VOLTAGE

56VAC

28VAC

28VAC