6. Remove the two transformer secondary

leads X2 and X3 (braided copper strap)
from the negative capacitor bank buss
bar using two 1/2 in. open end wrench-
es.

7. Disconnect and label all transformer

leads from the reconnect panel using a
3/8 in. open end wrench.

8. Disconnect and label all leads from the

input power switch.

9. Remove the power switch.

10. Disconnect thermostat leads #320 and

#320B from the SCR Rectifier.

PROCEDURE

1. Disconnect main input power to the

machine.

2. Remove the case side panels using a

3/8 in. nutdriver.

3. Test that the capacitors are discharged

using a volt ohmmeter. Polarity must
be observed.

4. Remove lead X1 from the left side SCR

heat sink assembly using a 1/2 in. sock-
et wrench, extender and universal
adapter. See Figure F.17.

5. Remove lead X4 from the right side

heat sink assembly using a 1/2 in. sock-
et wrench, extender and universal
adapter.

FIGURE F.17 — MAIN TRANSFORMER REMOVAL.

OUTPUT

CHOKE

LEAD

LEAD

X1

LEAD

X4

LEADS

X2 AND X3

POWER

ENHANCEMENT

CHOKE

MAIN

TRANSFORMER

PLUG-IN LEADS ARE
NOT SHOWN FOR
CLARITY.

NOTE:

OUTPUT

CHOKE

POSITIVE

LEAD

MAIN TRANSFORMER AND OUTPUT CHOKE

REMOVAL AND REPLACEMENT (continued)