Installation, Technical specifications – power mig 255 – Lincoln Electric POWER MIG 255 SVM144-B User Manual

Page 8

Advertising
background image

POWER MIG 255

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

A-2

INSTALLATION

A-2

75°C Copper Wire

75°C Copper Wire

in Conduit

in Conduit

Input Ampere

AWG (IEC) Sizes

AWG (IEC) Sizes

Input Voltage/

Fuse or Breaker

Rating On

(For lengths

(For lengths

Frequency (Hz)

Size (Super Lag)

Nameplate

up to 100 ft)

exceeding 100 ft)

208/60

60

50

8 (10 mm2)

6 (16 mm2)

230/60

60

46

10 (6 mm2)

8 (10 mm2)

460/60

30

24

14 (2.5 mm2)

12 (4 mm2)

575/60

25

19

14 (2.5 mm2)

12 (4 mm2)

NOTE: Use #10 AWG Grounding Wire

TECHNICAL SPECIFICATIONS – POWER MIG 255

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

Height

Width

Depth

Weight

31.79 in.

18.88 in.

38.78 in.

220 Ibs

808 mm

480 mm

985 mm

100 kg

PHYSICAL DIMENSIONS

Wire Speed

50 – 700 IPM (1.27 – 17.8 m/minute)

WIRE SPEED RANGE

Standard Voltage/Frequency

Input Current @ 200 Amp Rated Output Input Current @ 250 Amp Rated Output

208/230/60 Hz

41/37 Amps

50/46

230/460/575/60 Hz

41/20/16 Amps

50/24/19

Duty Cycle

Amps

Volts at Rated Amperes

40%

250 Amps

26 Volts

60%

200 Amps

28 Volts

100%

145 Amps

26 Volts

Welding Current Range

Maximum Open Circuit Voltage

Welding Voltage Range

(Continuous)

30 – 300 Amps

40 Volts

10-28 Volts

Advertising