POWER MIG 255

TROUBLESHOOTING & REPAIR

F-33

F-33

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

0 VOLTS

20.0 V

5 ms

MACHINE LOADED TO 220 AMPS AT 22 VDC

ABNORMAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
ONE OUTPUT SCR NOT FUNCTIONING

This is NOT a typical DC output voltage
waveform. One output SCR is not function-
ing. Note the increased ripple content. One
SCR gate was disconnected to simulate an
open or non-functioning output SCR. Each
vertical division represents 20 volts and
each horizontal division represents 5 mil-
liseconds in time. The machine was loaded
with a resistance grid bank.

NOTE: Scope probes connected at machine
output terminals: (+) probe to electrode, (-)
probe to work.

Volts/Div . . . . . . . . . . . . . . . . . . 20 V/Div

Horizontal Sweep . . . . . . . . . . 5 ms/Div

Coupling . . . . . . . . . . . . . . . . . . . . . . DC

Trigger . . . . . . . . . . . . . . . . . . . . Internal

SCOPE SETTINGS