TROUBLESHOOTING & REPAIR

F-4

F-4

WELDANPOWER 125

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Major physical or electrical dam-
age is evident.

1.

Contact your local Lincoln
Authorized Field Service
Facility.

1. Contact The Lincoln Electric

Service Dept. (216) 383-2531 or
1-800-833-9353 (WELD).

No weld output and no auxiliary
power. Engine operates normally.

1. Check brushes for wear. See

the Maintenance section of
this manual.

2. Check for loose or faulty con-

nections at brush holders.

1. Perform the Rotor Voltage

Test.

2. If the rotor voltage is low or

missing, check for the proper
flashing current. Perform the
Rotor Flashing Circuit Test.

3. Perform the Rotor Resistance

Test.

4. The field capacitor (C1) or recti-

fier bridge (D1) may be faulty.
Test or replace.

5. Test the rheostat (R1). Normal

resistance is 3.3 ohms.