OUTPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT

(continued)

11. With the 7/16" wrench, install the choke

lead and the #203 lead to the positive
heat sink.

12. With the 7/16" wrench, install the "N"

negative lead and the #204 lead to the
negative heat sink.

13. With the 7/16" wrench, install the heavy

leads W1 and W2 to the stud terminals.

14. Replace the top cover of the control box

and tighten the 8 sheet metal screws with
the 5/16" nut driver.