TROUBLESHOOTING & REPAIR

F-59

F-59

WELDANPOWER 125

RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

No Load RPM

Load RPM

Maximum Speed

3800

3500

Minimum Speed

3700

3300

WELDER/GENERATOR OUTPUT

1

Output Control

Field Volts

Field Amps

Open Circuit

Load Volts

Load Amps

Volts

RMS

Maximum

40 - 47

4.0 - 6.4

75 - 82

22 - 28

125 - 135

Minimum

70 - 78

23 - 27

40 - 55

AUXILIARY POWER RECEPTACLE OUTPUT

1

230 Volt Receptacle

115 Volt Receptacle

2

Output

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Control

Volts

Volts

Maximum

240 - 260

208 - 234

20.2 - 22.0

120 - 130

104 - 117

20.2 - 22.0

1

Current Control Dial set at MAXIMUM.

2

Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.