TROUBLESHOOTING & REPAIR

F-34

F-34

WELDANPOWER 125

CH1

0 volts

5 ms

50 volts

This is not the typical DC output
voltage waveform. Note the “gap” in
the waveform. One output diode was
disconnected to simulate an “open”
diode. Each vertical division repre-
sents 50 volts and that each horizon-
tal division represents 5 milliseconds
in time.

Note: Scope probes connected at
machine output terminals.

SCOPE SETTINGS

Volts/Div.....................50V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal

ABNORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

Advertising