Troubleshooting & repair – Lincoln Electric WELDANPOWER SVM 113-A User Manual

Page 70

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-32

F-32

WELDANPOWER 125

SCOPE SETTINGS

Volts/Div.....................50V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal

CH1

0 volts

5 ms

50 volts

This is the typical AC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 50 volts and that
each horizontal division represents 5
milliseconds in time.

Note: Scope probes connected at
machine 115 VAC receptacle.

1 Period = 16.2 ms @ 3700 rpm

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

Advertising