Engine will not start, Engine runs erratic or stops running, Troubleshooting – Lincoln Electric WELDANPOWER SVM 113-A User Manual

Page 46: Troubleshooting & repair, Caution

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-8

F-8

WELDANPOWER 125

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

ENGINE PROBLEMS

Engine will not start.

1. Make sure the RUN/STOP

Switch is in the “RUN” position.

2. Make sure the fuel shut off valve

is in the open position.

3. Make sure the engine has ade-

quate fuel and oil.

4. Adjust the choke to prevent car-

buretor flooding.

5. Check the spark plug wire for

loose or faulty connections.

1. Check the fuel line for breaks or

obstructions.

2. The spark plug may be faulty.

Replace.

3. Service the engine as outlined

in the Maintenance section of
this manual.

4. The engine ignition module may

be faulty. Consult Briggs &
Stratton Service.

Engine runs erratic or stops run-
ning.

1. The oil level may be low, acti-

vating the engine oil level shut-
down system. Check oil level.

2. Check the spark plug wire for

loose or faulty connection.

3. The spark plug may be faulty.

Replace.

4. The fuel and air mixture may be

out of adjustment. Consult the
Briggs & Stratton Owner’s
Manual.

5. The fuel supply may be conta-

minated with water.

1. If the oil level is correct, the oil

level shutdown switch may be
faulty. Remove the lead running
from the oil level switch to the
ignition module. If the engine
runs normally, the oil level
switch is faulty. Replace. DO
NOT OPERATE THE ENGINE
WITHOUT OIL LEVEL PRO-
TECTION.

2. The engine may require service

to the head or carburetor.

Advertising