TROUBLESHOOTING & REPAIR

F-31

F-31

WELDANPOWER 125

CH1

0 volts

5 ms

50 volts

SCOPE SETTINGS

Volts/Div.....................50V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal

This is the typical output voltage gen-
erated from a properly operating
machine. Note that each vertical
division represents 50 volts and that
each horizontal division represents 5
milliseconds in time.

Note: Scope probes connected at
machine output terminals.

NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM