Setup, Step e: performing automatic calibration, Step distances levels distances & levels – Lexicon MC-12 Digital Controller Lexicon MC-12 User Manual

Page 88: E-1 e-2

Advertising
background image

SETUP

Lexicon

3-46

Step E: Performing Automatic Calibration

MAIN MENU

MODE ADJUST
AUDIO CONTROLS
SETUP

SETUP

SETUP

INPUTS
SPEAKERS
REAR PANEL CONFIG
DISPLAYS
VOLUME CONTROLS
TRIGGERS
LOCK OPTIONS

SPEAKERS

AUTO SPEAKER SETUP

DISTANCES & LEVELS
DISTANCES
OUTPUT LEVELS

PLACE MICROPHONES

IN PRIMARY LISTENING

POSITIONS

AUTO SPEAKER SETUP

TEST WILL BEGIN IN

10

PRESS V TO SKIP

COUNTDOWN

AUTO SPEAKER SETUP

!CAUTION!

HIGH AUDIO LEVELS

YOU WILL HAVE 10 SEC

TO LEAVE THE ROOM OR

SIT QUIETLY

PRESS V TO BEGIN

COUNTDOWN

10

SPEAKER SETUP

SET CROSSOVERS
CHECK MICROPHONES
AUTOMATIC
MANUAL

SET CROSSOVERS

BEFORE CALIBRATING

AUTOMATIC

Follow the instructions in the appropriate table column below to perform the desired automatic calibration procedure.

STEP

DISTANCES

LEVELS

DISTANCES & LEVELS

Select the SPEAKER SETUP menu AUTOMATIC option as shown in the menu illustration above.

If a successful microphone check has been performed, the AUTO SPEAKER SETUP menu shown above will open on the on-screen
display. Press the

and

arrow buttons to highlight the desired automatic calibration option. Then, press the

arrow button

to select this option. Refer to the table on page 3-34 for more information about automatic calibration options.

If a successful microphone check has not been performed, one of the error messages shown at the right will open on the on-screen
display, indicating that a successful microphone check is required before automatic calibration can be performed. If this occurs,
begin with Step A: Connecting the Microphones on page 3-35 to perform the microphone check.

The following AUTO SPEAKER SETUP screens will open on the on-screen display before automatic calibration is performed:

The !CAUTION! HIGH AUDIO LEVELS screen shown above will open on the on-screen display, indicating that the MC-12 generates loud calibration noise
signals during automatic calibration. If the signals become too loud, press the

arrow button to cancel automatic calibration. Press the

arrow button

to open the next AUTO SPEAKER SETUP screen.

The countdown screen shown above will open on the on-screen display, activating a 10-second countdown to automatic calibration. Press the

button

to skip the countdown and begin automatic calibration. Otherwise, it is possible to leave the listening space without affecting automatic calibration results.
The MC-12 will automatically activate automatic calibration when the countdown ends. It is recommended to return to the listening space about 10
minutes later to avoid interrupting the automatic calibration procedure.

MIC CHECK REQUIRED

FOR AUTO CALIBRATION

NO MICROPHONES

DETECTED

E-1

E-2