SETUP

Lexicon

3-48

STEP

DISTANCES

LEVELS

DISTANCES & LEVELS

When the MC-12 is finished calibrating
speaker distances, the AUTO DISTANCES
screen shown above will open on the
on-screen display, indicating the results for
each individual speaker.

A value indicates that no errors occurred
during the calibration procedure.

An ERROR message indicates that – although
a value was calculated – at least one error
occurred during the calibration procedure.

Press the

and

arrow buttons to

highlight the desired speaker calibration
parameter. Then, press the

arrow button

to view more detailed results for the selected
speaker. A message similar to the one
shown above will open on the on-screen
display.

Refer to the table on page 3-50 for
information about all possible speaker
calibration messages.

When the MC-12 is finished calibrating
speaker distances and output levels, the
AUTO SPEAKER SETUP results screen shown
above will open on the on-screen display,
indicating the results for each calibration
procedure.

An OK message indicates that no errors
occurred during the calibration procedure.

An ERROR message indicates that –
although a value was calculated – at least
one error occurred during the calibration
procedure.

Press the

and

arrow buttons to

highlight the desired calibration procedure.
Then, press the

arrow button to select

this procedure.

Selecting DISTANCES opens the AUTO
DISTANCES screen shown in the DISTANCES
column (left).

Selecting the LEVELS option opens the
AUTO LEVELS screen shown in the LEVELS
column (right).

Refer to the instructions in the appropriate
column to view more detailed results for
each individual speaker.

When the MC-12 is finished calibrating output
levels, the AUTO LEVELS screen shown above
will open on the on-screen display, indicating
the results for each individual speaker.

A value indicates that no errors occurred
during the calibration procedure.

An ERROR message indicates that – although
a value was calculated – at least one error
occurred during the calibration procedure.

Press the

and

arrow buttons to

highlight the desired speaker calibration
parameter. Then, press the

arrow button

to view more detailed results for the selected
speaker. A message similar to the one
shown above will open on the on-screen
display.

Refer to the table on page 3-50 for
information about all possible speaker
calibration messages.

E-5

Step E: Performing Automatic Calibration

(continued from page 3-47)

Refer to the table on page
3-50 for information about
all possible speaker calibration
messages.

AUTO DISTANCES

FRONT LEFT

12.0ft

CENTER

10.5ft

FRONT RIGHT

12.0ft

SIDE RIGHT

4.5ft

REAR RIGHT

ERROR

REAR LEFT

6.0ft

SIDE LEFT

4.5ft

MONO SUB

N/A

SUB RIGHT

N/A

LFE

N/A

FRONT LEFT

12.0ft

FRONT LEFT

OK

Refer to the table on page
3-50 for information about
all possible speaker calibration
messages.

AUTO LEVELS

FRONT LEFT

-2.0dB

CENTER

ERROR

FRONT RIGHT

-2.0dB

SIDE RIGHT

-4.5dB

REAR RIGHT

-3.0dB

REAR LEFT

-3.0dB

SIDE LEFT

-4.5dB

MONO SUB

N/A

SUB RIGHT

N/A

LFE

N/A

FRONT LEFT

-2.0dB

FRONT LEFT

OK

AUTO SPEAKER SETUP

DISTANCES

OK

LEVELS

ERROR

AUTO VALUES APPLIED

PRESS V TO VIEW

DETAILS