FIGURE F.1 – OUTPUT SELECTOR SWITCH TERMINALS

MAIN TRANSFORMER TEST (continued)

TROUBLESHOOTING AND REPAIR

F-12

F-12

Power MIG® 215XT

WARNING

PROCEDURE

THE ON/OFF POWER SWITCH will be “hot”
during these tests.

NOTE: Secondary

voltages

will

vary

proportionately with the primary input
voltage.

1. Disconnect the main input power supply to the

machine.

2. Remove the case top and side panels with a 3/8”

nutdriver.

3. Remove the tool tray with a 5/16” nut driver.

4. Locate leads X2 thru X8 located on the output

selector switch. See Figure F.1.

5. Locate lead X1 located on the output rectifier

assembly. See Figure F.2.

6. Locate leads X9 and X10. See Figure F.3.

7. Connect main input power to the machine.

8. Turn the Power MIG® 215XT ON/OFF Power

Switch to the ON position.

9. Carefully make the following voltage tests. See

Table F.1.

10. Turn Off the machine.

11. If any of the voltages are incorrect or missing,

check for loose or broken connections between
the main transformer and the test points.

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts

such as output terminals or inter-
nal wiring.

• All input power must be electrical-

ly disconnected before proceed-
ing.

WARNING