Depress locking tab on mounting pin, Troubleshooting and repair – Lincoln Electric POWER MIG 11521 User Manual

Page 66

Advertising
background image

DEPRESS
LOCKING TAB ON
MOUNTING PIN

FIGURE F.8 – CONTROL BOARD MOUNTING PINS

CONTROL BOARD REMOVAL AND REPLACEMENT PROCEDURE

(continued)

PROCEDURE

1. Remove power to the machine.

2. Using a 5/16” nutdriver, remove the three

screws securing the tool tray.

3. Locate the control board.

4. Disconnect all associated plugs and leads con-

nected to the control board.

5. Depress the retaining pins on the sides of the

four nylon mounts to release the control board.
See Figure F.8.

6. Carefully remove the control board.

7. Mount the new board to the nylon mounting

pins.

8. Reconnect any plugs or leads previously

removed.

9. Replace the tool tray previously removed.

TROUBLESHOOTING AND REPAIR

F-28

F-28

Power MIG® 215XT