This is a typical DC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 10 volts
and that each horizontal division rep-
resents 5 milliseconds in time. The
machine was loaded with a resistance
grid bank.

Note: Scope probes connected at

machine output terminals: (+)
probe to electrode, (-) probe to
work.

SCOPE SETTINGS

Volts/Div.....................10V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

(MAX TAP “G”)

0 volts

5ms

10.0V

TROUBLESHOOTING AND REPAIR

F-23

F-23

Power MIG® 215XT

MACHINE LOADED TO 200 AMPS AT 22 VDC