Troubleshooting and repair, Normal open circuit voltage waveform (max tap “g”) – Lincoln Electric POWER MIG 11521 User Manual

Page 62

Advertising
background image

This is a typical DC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 20 volts
and that each horizontal division rep-
resents 1.0 milliseconds in time.

Note: Scope probes connected at

machine output terminals: (+)
probe to electrode, (-) probe to
work.

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep ..1.0 ms/Div.
Coupling.............................DC
Trigger.........................Internal

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (MAX TAP “G”)

0 volts

1.0 ms

20.0V