MAIN TRANSFORMER REMOVAL AND REPLACEMENT PROCEDURE

(continued)

15. Carefully maneuver the main transformer out

the left side of the machine.

NOTE: Two people may be needed to maneuver

the main transformer out of the machine.

REPLACEMENT

1. Carefully maneuver the new main transformer

back into the machine and onto its mounting
studs.

2. Using a 1/2” nutdriver, mount the main trans-

former in its proper position.

3. Reconnect leads 118 and 121 previously

removed.

4. Using a 5/16” nutdriver, close the rear access

panel previously opened.

5. Reconnect lead X1 to the output diode bridge

rectifier.

6. Reconnect leads X8, X7, X6, X5, X4, X3, & X2

previously removed from the switch assembly.

7. Reconnect lead H1B and the other associated

lead connected to the same terminal. These
leads are connected to the ON/OFF switch.

8. Replace any necessary cable ties and wiring

harnesses.

9. Reconnect leads X9, X10, 104B, & 104C. See

Wiring Diagram.

10. Using a 5/16” nutdriver, replace the tool tray.

11. Using a 3/8” nutdriver, replace both sides of the

case wraparound cover.

TROUBLESHOOTING AND REPAIR

F-43

F-43

Power MIG® 215XT

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising