Troubleshooting and repair, Output contactor – Lincoln Electric POWER MIG 11521 User Manual

Page 88

Advertising
background image

107A

106C

106B

Output
Contactor

FIGURE F.23 – OUTPUT CONTACTOR LEADS

OUTPUT CONTACTOR REMOVAL AND REPLACEMENT PROCEDURE

(continued)

PROCEDURE

1. Using a 5/16” nutdriver, remove the three

screws securing the tool tray.

2. Locate the output contactor. See Figure F.23.

3. Using a 7/16” wrench, label and remove the two

thick black leads at the top of the output con-
tactor. Note lead and washer placement for
reassembly.

4. Remove lead 107A and note lead placement.

See Figure F.23.

5. Remove leads 106B and 106C. See Figure

F.23.

6. Using a 7/16” wrench, remove the three mount-

ing bolts from the output contactor. Note wash-
er positions for replacement. See Figure F.24.

7. Replace output contactor.

8. Using a 7/16” wrench, mount the new output

contactor in its proper location.

9. Reconnect leads 106B, 106C, & 107A to their

proper terminals. See Wiring Diagram.

10. Reconnect the two thick black leads previously

removed from the top of the output contactor.

11. Replace the tool tray using a 5/16” nutdriver.

TROUBLESHOOTING AND REPAIR

F-50

F-50

Power MIG® 215XT