This is NOT a typical DC output volt-
age waveform. The output capacitors
are not functioning. Note the lack of
“filtering” in the output waveform. The
output capacitor bank was disconnect-
ed. Each vertical division represents
20 volts and each horizontal division
represents 5 milliseconds in time.

Note: Scope probes connected at

machine output terminals: (+)
probe to electrode, (-) probe to
work.

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

ABNORMAL OPEN CIRCUIT VOLTAGE

OUTPUT CAPACITOR BANK NOT FUNCTIONING (MAX TAP “G”)

0 volts

5ms

20.0 V