INSTALLATION

INVERTEC V250-S

A-4

POWER INPUT CONNECTION FOR 50/60 HZ
MACHINES

1. Connect terminal marked to earth ground

per National Electric Code.

2. Connect the supply lines to the line switch. Torque

to 3.0 Nm.

3. Install in accordance with all local and national

electric codes.

The Invertec V250-S 50/60 Hz machine is supplied
with one cord connector. The cord connector provides
a strain relief for the input power cord as it passes it
through the rear access hole. The cord connector is
designed for a cord diameter of 7.9 to 27.2mm (.310
to 1.070 in).

Strip away outer jacket of cord, trim fillers and insert
conductors through cord connector. The jacketed por-
tion of the cord must go through the cord connector.
Tighten both connector screws.

INPUT FUSE AND SUPPLY WIRE

Refer to the

Technical Specifications page at the

beginning of this chapter for the proper fuse sizes and
supply cable sizes.

• Fuse the input circuit with recommended super lag

fuses or delay type circuit breakers.

• Install the proper fuse in the fuse holder in the main

disconnect panel.

INPUT VOLTAGE RECONNECT
PROCEDURE

When received directly from the factory, units are con-
nected for the highest input voltage, 440 VAC for
50/60 Hz machines and 460 VAC for 60 Hz machines.
If 440 or 460 VAC is the desired input, then the
machine may be connected to the power system with-
out any setup required inside the reconnect door.
However, verify the connection with the following pro-
cedure. For other voltages refer to the instructions
located on the Reconnect Panel Access Door or fol-
low the instructions below.

Failure to follow these instructions can cause immedi-
ate failure of components within the welder.

------------------------------------------------------------------------

1. Open the access door on the right side of the

machine.

2. For 200-230: Position the large switch to 200-230.

For 380-460: Position the large switch to 380-460.

3. Move the “A” lead to the appropriate terminal.

Refer to figure A.1 below.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

THE LINCOLN ELECTRIC CO. CLEVELAND, OHIO U.S.A.

.

.

.

.

Do not touch electrically live parts.

Only qualified persons should install,

use or service this equipment.

RECONNECT PROCEDURE

1. BE SURE POWER SWITCH IS OFF.

200-208V

220-230V

380-415V

440-460V

'A'

INPUT VOLTAGE RANGE.

removed.

Do not operate with wraparound

inspecting or servicing machine.

Disconnect input power before

IF MACHINE CEASES TO OPERATE (NO METER, NO FAN)

2. CONNECT LEAD 'A' TO DESIRED

3. POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.

S21230

AND THERE IS NO OTHER KNOWN FAILURE: CHECK FUSE;

VOLTAGE=380-460V

VOLTAGE=200-230V

REPLACE WITH SPECIFIED FUSE.

A

CAUTION

Figure A.1 Input Voltage Reconnect Instructions