The machine will not produce more than 200 amps, Troubleshooting & repair, Caution – Lincoln Electric INVERTEC V250-S User Manual

Page 40

Advertising
background image

F-8

TROUBLESHOOTING & REPAIR

F-8

INVERTEC V250-S

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

The machine will not produce more
than 200 amps.

1. This may be normal operation. If

the output current exceeds 290
amps, an electronic protection
circuit will reduce the current to
less than 200 amps. The
machine will continue to produce
this low current until the
protection circuit is reset. Reset
occurs when the output load is
removed.

2. Check the input voltage and input

voltage reconnect procedures.
See

Input Voltage Reconnect

Procedure.

3. Check for loose or faulty welding

cables.

1. Perform the

Output Diode Test.

2. The control board may be faulty.

Replace.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC