background image

B-4

OPERATION

B-4

6. Arc Force - This control functions in SMAW modes

to adjust the Arc Force. The arc is soft at the mini-
mum settings and more forceful or driving at the
maximum settings. Higher spatter levels may be
present at the maximum settings.

7. Output Terminals - These quick disconnect termi-

nals provide connection points for the electrode and
work cables. Refer to

Output Connections in the

Installation chapter for proper cable sizes. For
positive polarity welding connect the electrode
cable to the positive terminal and the work cable to
the negative terminal. To weld negative polarity
reverse the electrode and work cables.

8. Thermal Shutdown Indicator - This light will illumi-

nate if an internal thermostat has been activated.
Machine output will return after the internal
components have returned to a normal operating
temperature. See

Thermal Protection later in this

chapter.

CONSTANT CURRENT PROCESSES

MANUAL ARC WELDING (STICK)

The Invertec may be utilized as a manual DC arc
welder with the electrode cable, work cable, and elec-
trode holder being the only equipment required.

AIR CARBON ARC CUTTING

Air carbon arc cutting may be performed with the
Invertec within its output rating using 5/32" (3.9mm)
and 3/16" (4.7mm) diameter carbon rods. Output
cables, an air carbon arc electrode cable assembly,
and a source of compressed air are required.

NOTE:
1. Best performance will be at settings of 200 amps

and below.

2. The electronic protection circuit in the V250S will

limit the current to approximately 290 amps.

TIG WELDING

The V250S is capable of touch start TIG welding. An
electrode cable, work cable, Arc Start Switch or
Amptrol, TIG torch, and gas supply with regulator are
required. Refer to

Accessories section of this manual.

Touch starting is done as follows:

1. Place the shield cup edge on the work piece.
2. Rock the tungsten down to touch.
3. Trigger the output.
4. Gently rock back the tungsten from the work-

piece.

Note: The short circuit current is limited to 25 amps to

aid in touch starting. Panel output control
becomes the current limit setting when in
remote control

INVERTEC V250-S

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

RECOMMENDED ARC FORCE/INDUCTANCE

SETTINGS FOR SELECTED APPLICATIONS

FULL RANGE IS 1-10. 1 is VERY SOFT,

10 IS VERY CRISP

Nominal

Recommended

Mode

Process

Setting

Adjustment Range

CC SMAW 1

EXX18 thru

5

1 (gentle, may stick) to 9

(soft)

EXX28 stick

(forceful, more spatter)

CC SMAW 2

EXX10 thru

6

3 to 10

(crisp)

EXX14 stick

Air Carbon Arc

1

None

Cutting

Advertising