F-44

TROUBLESHOOTING & REPAIR

F-44

PROCEDURE

1. Remove input power to the V250-S.

2. Perform

Filter Capacitor Discharge

Procedure detailed in Maintenance
Section.

3. Locate the control board and the five

molex type plugs that are connected
to it. See Figure F.13.

4. Carefully remove the five molex type

plugs by depressing the locking tabs
and gently extracting the plugs from
the P.C. board receptacles.

5. Using the needle nose-pliers and

small screwdriver gently remove the
control board from the six mounting
pins by depressing the tabs on the
mounting pins and sliding the board
from the pins. See Figure F.13.

Note: Be sure to observe static elec-
tricity precautions when handling
P.C. boards.

6. When replacing the control board

align the mounting holes with the
mounting pins and gently slide the
P.C. board onto the mounting pins
until the board “snaps” onto the
mounting pins.

Note: Be sure to observe static elec-
tricity precautions when handling
P.C. boards.

7. Replace the five molex type plugs in

their appropriate receptacles.

8. Inspect, clear and secure all leads in

preparation for case wrap-around
reassembly.

9. Using the 5/16” nut-driver replace

the case wrap-around.

CONTROL BOARD REMOVAL AND REPLACEMENT (continued)

INVERTEC V250-S

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

G2666-[ ]

V250S CONTROL

J1

J2

J5

J3

J4

DEPRESS LOCKING TAB
ON MOUNTING PIN

SIX MOUNTING TABS

Figure F.13

Control Board Plugs and Mounting Pins