Theory of operation, Precharge and protection – Lincoln Electric INVERTEC V250-S User Manual

Page 27

Advertising
background image

E-3

THEORY OF OPERATION

E-3

PRECHARGE AND PROTECTION

The input voltage is rectified and the DC voltage is
applied, through the reconnect switch, to the power
board. The power board contains precharging circuit-
ry for the safe charging of the input filter capacitors.
Once the capacitors are precharged and balanced the
control board activates the CR1 input relay which con-
nects full input power to the filter capacitors. When
the filter capacitors are fully charged they act as
power supplies for the IGBT switching circuit. The
Insulated Gate Bipolar Transistors supply the main
transformer primary windings with DC current flow.
See

IGBT Operation Discussion and diagrams in

this section.
The power board also monitors the filter capacitors for
voltage balance and/or overvoltage and, if either
should occur, sends the appropriate signal to the con-
trol board to deactivate the CR1 input relay. The
machine output will also be disabled.

FIGURE E.2 PROTECTION AND PRE-CHARGE CIRCUITS

INVERTEC V250-S

INPUT

LINE

SWITCH

INPUT

RECTIFIER

R

E

C

O

N

N

E

C

T

S

W

I

T

C

H

AUXILIARY

TRANSFORMER

FAN

MOTORS

POWER BOARD

MAIN

TRANSFORMER

SHUNT

POSITIVE

OUTPUT

TERMINAL

NEGATIVE

OUTPUT

TERMINAL

THERMAL

LIGHT

REMOTE

RECEPTACLE

OUTPUT

CONTROL

STRIKE

CONTROL

ARC

FORCE

CONTROL

MODE

SWITCH

LOCAL/

REMOTE

SWITCH

RELAY

CAPACITOR

CAPACITOR

IGBT

IGBT

IGBT

IGBT

CURRENT

TRANSFORMER

18VAC

GATE SIGNALS

THERMOSTATS

O

V

E

R

V

O

L

T

A

G

E

PROTECTION SIGNAL

CR1 RELAY DRIVE SIGNAL

CR1

IGBT

CONTROL BOARD

A"

L

E

A

D

"

F
E
E

D
B
A
C
K

F
E
E

D
B
A
C
K

NOTE: Unshaded areas of block logic diagrams are the subject of discussion.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Advertising