TROUBLESHOOTING & REPAIR

F-6

INVERTEC V250-S

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Output turns on momentarily, then
switches off and repeats cycle.

Remote output control not
functioning. The machine operates
normally on LOCAL control.

1. Check the input voltages and

reconnection procedures. Make
sure the input voltage is correct
for the machine. See

Input

Voltage Reconnect Procedure.

2. Check or replace remote control

device. (If used)

1. Make sure the Local/Remote

switch (S3) is in the REMOTE
position.

2. The remote control device may

be faulty. Replace.

1. Check Local/Remote switch (S3)

and associated wiring for loose or
faulty connections.

2. Check Mode Switch (S2) and

associated wiring for loose or
faulty connections.

3. If the machine is connected for

380VAC input or higher, perform
the

Capacitor Balance Test.

4. The power board may be faulty.

Replace.

5. The control board may be faulty.

Replace.

1. Check the Local/Remote switch

(S3) and the associated wiring.
See wiring diagram.

2. Check for loose or faulty

connections at the remote control
receptacle.